- Flow range: 25 cc/min to 45 liters/min (0.006 to 12 gpm)
- Accuracy (at 30 cP): ± 0.3% of reading over a 100:1 range
- Maximum Operating Pressure: 414 bar (6000 psi)
G045 Gear Flow Meter
Features
- Flow range: 25 cc/min to 45 liters/min (0.006 to 12 gpm)
- Accuracy (at 30 cP): ± 0.3% of reading over a 100:1 range
- Maximum Operating Pressure: 414 bar (6000 psi)
- Displacement: 13.5 cc/rev (0.82 in3/rev)
- Weight: 3.7 kg 8.1 lbs
- Recommend Filtration 30 micron 475 mesh
- Port Size: 1/2″ NPT or #8 SAE
- Fluids: Most non aqueous, hydrocarbon based liquids
Materials of Construction
- Body: Stainless steel, type 303
- Gears and shafts: Stainless steel, type 17-4
- Bearings: All ball bearings, 440C stainless steel
- Seals: Viton® “O” rings – standard; Teflon®, Perfluoroelastomer – optional
Transmitter Variations (dependent on model #)
Signal Type
Frequency
- Output: 5V pulse, single phase (current sinking, also available)
- Resolution: 70,000 pulses/liter
- Temperature Rating:
- Standard: 90°C ; Two Piece High Temp: 155 °C ; Two Piece Ultra High Temp: 225 °C
Quadrature
- Output: 5V pulse, two phase
- Resolution: 35000 pulses/liter/phase
- Linearization: Linearized
- Temperature Rating:
- Standard: 90°C ; Two Piece High Temp: 155 °C ; Two Piece Ultra High Temp: 225 °C
Voltage
- Output: 0-10Vdc
- Resolution: Uni or bidirectional
- Linearization: Linearized
- Temperature Rating:
- Standard: 90°C ; Two Piece High Temp: 155 °C ; Two Piece Ultra High Temp: 225 °C
Current
- Output: 0-20mA
- Resolution: Uni or bidirectional
- Linearization: Linearized
- Temperature Rating:
- Standard: 90°C ; Two Piece High Temp: 155 °C ; Two Piece Ultra High Temp: 225 °C
Compliance: CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex d IIB Tx Gb as well as UL, cUL certification for Class 1, Division 1, Groups C and D, Tx
Maximum temperature rating for ATEX certified transmitters is 130°C